Fixed firefighting systems - Foam systems - Part 2: Design, construction and maintenance


Abstract/Scope:

This document specifies the requirements and describes the methods for design, installation, testing and maintenance of low, medium, and high expansion foam fire extinguishing systems. Foam systems may be used to suppress the release of toxic vapours but this application is outside the scope of this document.

This document provides guidance for the design of various foam systems available to persons with knowledge and experience in determining the selection of foam fire extinguishing systems which will be effective in protecting specific hazard configurations. For the application of this standard, a risk assessment by a qualified and experienced person should be performed for both new and existing systems, however the risk assessment is outside the scope of this document.

This document does not cover a risk analysis carried out by a competent person. Nothing in this document is intended to restrict new technologies or alternative arrangements, provided that the level of foam system performance prescribed in this standard is not lowered, and supported by documented evidence/test reports.

All foam systems are generally unsuitable for the following: – chemicals, such as cellulose nitrate, that release sufficient oxygen or other oxidizing agents which can sustain combustion; – energized unenclosed electrical equipment; – metals such as sodium, potassium and sodium-potassium alloys which are reactive to water; – hazardous, water-reactive materials such as triethyl-aluminium and phosphorous pentoxide; – combustible metals such as aluminium and magnesium.

Link: EN 13565-2:2018+AC:2019

Correction/Amendment: EN 13565-2:2018+AC:2019/AC:2021

 

Source: European Committee for Standardization

Special publications

Water mist fire extinguishing systems – sustainable technology in the fire protection industry
  The use of water mist systems as a modern sustainable technology in the firefighting industry has grown significantly over the last two decades. Water...
Low pressure water mist – the modern approach in firefighting industry
For the last thirty years, water mist fire protection has evolved from a theory to an increasingly widely accepted alternative to traditional water, foam or...

Norms and standards

Standards: EN 14972-1:2020
Abstract/Scope This document specifies requirements and gives recommendations for the design, installation, inspection and maintenance of all types of fixed land based water mist systems....
Standards: EN 54-1:2021
  Abstract/Scope: This document defines the terms and definitions that are used throughout the EN 54 series of standards. It gives the principles on which...
Standards: EN 16750:2017+A1:2020
Abstract/Scope: This European standard specifies oxygen reduction systems that are used as fire prevention systems by creating an atmosphere in an area which is having...
Fire-TechInfo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.